Root Cause Identified
Actuator speed regulation issue.
🚚
Who can fix this
Machine Distributor
📖
Manual
Section 3.1.2 – System Functions Open in manual

Hydraulics are adequate but actuators still move slowly — likely an internal flow regulation problem.

Recommended Actions
  1. 1 Internal speed controllers or flow regulators on the hydraulic valves may need adjustment.
  2. 2 Contact the distributor or the machine manufacturer.

For further issues…